Product Description
Specification
| CMRR Common Mode Rejection Ratio | 80 dB |
| Width | 6.35 mm |
| Vos Input Offset Voltage | 2.5 mV |
| Unit Weight | 0.057419 oz |
| Supply Voltage Min | 9 V |
| Supply Voltage Max | 40 V |
| Subcategory | Amplifier ICs |
| Package Case | PDIP-16 |
| Number of Channels | 1 Channel |
| Mounting Style | Through Hole |
| Minimum Operating Temperature | - 40 C |
| Maximum Operating Temperature | + 85 C |
| Length | 19.3 mm |
| Ib Input Bias Current | 250 nA |
| Height | 4.57 mm |
Precision Signal Conditioning for RTD SensorsThe XTR103AP is engineered to interface seamlessly with 3-wire platinum RTD sensors ranging from 100 to 1k. Its high input impedance and low offset voltage ensure that signal integrity is maintained, providing reliable and highly accurate temperature measurements even in demanding industrial environments.
Versatile and Reliable Industrial ApplicationDesigned with features such as fast response time, excellent linearity, and robust build quality, the XTR103AP fits a variety of temperature transmitter and industrial process control systems. Its compact DIP-8 form factor allows for straightforward integration into both new and existing designs, catering to industrial requirements in India.
Comprehensive Protection and RoHS ComplianceEquipped with ESD protection and compliant with RoHS guidelines, the XTR103AP prioritizes safety and environmental responsibility. This makes it a dependable solution for manufacturers, distributors, and suppliers seeking a secure and sustainable choice for industrial signal conditioning needs.
FAQs of XTR103AP:
Q: How does the XTR103AP enhance temperature measurement accuracy with RTD sensors?
A: The XTR103AP incorporates a high input impedance and a precise on-chip current source to supply stable excitation to 3-wire platinum RTD sensors (100 to 1k). Its low offset voltage and excellent common-mode rejection ratio (min. 86dB at 60Hz) minimize errors, ensuring highly accurate and linear temperature-to-voltage conversion.
Q: What is the typical output type and voltage range provided by the XTR103AP?
A: The XTR103AP delivers a linear single-ended voltage output ranging from 0V to 4V, making it suitable for direct interfacing with analog measurement or monitoring systems commonly used in industrial process control.
Q: When should I choose the XTR103AP for my signal conditioning needs?
A: Select the XTR103AP when you require precise, reliable, and robust signal conditioning for 3-wire platinum RTD sensors in industrial temperature transmitter or process control applications, especially where low drift, fast response, and compact integration are priorities.
Q: Where can the XTR103AP be installed, and what is its package type?
A: The XTR103AP comes in a standard DIP-8 through-hole package, making it suitable for installation on PCBs that support DIP components. Its miniature size enables easy integration into a broad range of industrial measurement instruments and transmitter modules.
Q: What power supply requirements must be met for the XTR103AP to operate effectively?
A: The device operates on a dual power supply, accepting 5V to 18V DC. Using clean, regulated DC supplies ensures stable operation and optimal accuracy in signal conversion outputs.
Q: How does the XTR103AP ensure safety and longevity in industrial settings?
A: The XTR103AP integrates ESD protection and is RoHS compliant, which guards against electrostatic discharge and ensures environmentally safe operation. Its wide operating temperature range (40C to +85C) and robust construction support reliable performance in challenging industrial environments.
Q: What benefits does the XTR103AP provide for distributors and manufacturers in India?
A: Distributors and manufacturers benefit from the XTR103APs precision, small footprint, and RoHS compliance, which simplify design, enable versatile use in various industrial applications, and align with regulatory and sustainability goals in India.